{"id":6823,"date":"2021-01-14T14:26:06","date_gmt":"2021-01-14T14:26:06","guid":{"rendered":"http:\/\/www.powertekpdus.com\/ressourcen\/firmware-downloads\/"},"modified":"2026-06-22T09:11:01","modified_gmt":"2026-06-22T09:11:01","slug":"firmware-downloads","status":"publish","type":"page","link":"https:\/\/www.powertekpdus.com\/de\/ressourcen\/firmware-downloads\/","title":{"rendered":"Last firmware updates"},"content":{"rendered":"<p>[vc_row content_width=&#8220;grid&#8220; css=&#8220;.vc_custom_1612187139645{margin-top: 50px !important;margin-bottom: 50px !important;}&#8220;][vc_column][vc_column_text]<\/p>\n<h2>GIGA PDUs FIRMWARE<\/h2>\n<p>[\/vc_column_text][vc_empty_space height=&#8220;20px&#8220;][vc_column_text css=&#8220;.vc_custom_1612194577707{padding-bottom: 25px !important;}&#8220;]Download the latest firmware version:[\/vc_column_text][vc_row_inner content_width=&#8220;grid&#8220;][vc_column_inner width=&#8220;1\/2&#8243; css=&#8220;.vc_custom_1612192860734{padding-bottom: 15px !important;}&#8220;][vc_column_text]LAST FIRMWARE UPGRADE<\/p>\n<p>Install this file if you already have version 40a29 or 50axxxx<\/p>\n<p>1- Install GIGA SNMP on Advanced &#8212; Maintenance menu &#8212; Firmware Update<\/p>\n<p>2- Install Inlet&amp;Oultet on Advanced &#8212; Inlet &amp; Oultet upgrade[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8220;1\/2&#8243;][vc_btn title=&#8220;GIGA SNMP DOWNLOAD&#8220; style=&#8220;custom&#8220; custom_background=&#8220;#145c9f&#8220; custom_text=&#8220;#ffffff&#8220; shape=&#8220;square&#8220; link=&#8220;url:https%3A%2F%2Fwww.powertekpdus.com%2Fwp-content%2Fuploads%2F2026%2F06%2FPWT-v0.50a14-20260514.bin|target:_blank&#8220;][vc_btn title=&#8220;INLET \/ OUTLET DOWNLOAD&#8220; style=&#8220;custom&#8220; custom_background=&#8220;#145c9f&#8220; custom_text=&#8220;#ffffff&#8220; shape=&#8220;square&#8220; link=&#8220;url:https%3A%2F%2Fwww.powertekpdus.com%2Fwp-content%2Fuploads%2F2025%2F01%2FMCU-FW-IMG-v1.0.32_20241216.zip|target:_blank&#8220;][\/vc_column_inner][\/vc_row_inner][vc_row_inner content_width=&#8220;grid&#8220;][vc_column_inner width=&#8220;1\/2&#8243; css=&#8220;.vc_custom_1612192860734{padding-bottom: 15px !important;}&#8220;][vc_column_text]Kernel Upgrade<\/p>\n<p>Install this version first if you have version 40a28 or older<\/p>\n<p>1- Install GIGA SNMP on Advanced &#8212; Maintenance menu &#8212; Firmware Update<\/p>\n<p>[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8220;1\/2&#8243;][vc_btn title=&#8220;KERNEL UPGRADE DOWNLOAD&#8220; style=&#8220;custom&#8220; custom_background=&#8220;#145c9f&#8220; custom_text=&#8220;#ffffff&#8220; shape=&#8220;square&#8220; link=&#8220;url:https%3A%2F%2Fwww.powertekpdus.com%2Fwp-content%2Fuploads%2F2025%2F12%2FPWT_NKS-v0.40a29-20250227-enc_fw.bin|target:_blank&#8220;][\/vc_column_inner][\/vc_row_inner][vc_empty_space height=&#8220;50px&#8220;][vc_column_text]<\/p>\n<h2>Firmware history<\/h2>\n<p>[\/vc_column_text][vc_empty_space height=&#8220;20px&#8220;][vc_column_text css=&#8220;.vc_custom_1779183351725{padding-bottom: 25px !important;}&#8220;]<\/p>\n<table width=\"1286\">\n<tbody>\n<tr>\n<td width=\"105\">Date<\/td>\n<td width=\"105\">Board<\/td>\n<td width=\"132\">Ver.<\/td>\n<td width=\"944\">Description<\/td>\n<\/tr>\n<tr>\n<td>2026\/5\/15<\/td>\n<td>SNMP Board<\/td>\n<td>0.50a14<\/td>\n<td width=\"944\">1. Support OAuth 2.0 function.<br \/>\n2. Fixed the DNS retrieved from DHCP cannot update the PDU.<br \/>\n3. Fixed send DHCP renewal twice problem.<br \/>\n4. Fixed sends a renewal for an outdated lease problem.<\/td>\n<\/tr>\n<tr>\n<td>2026\/3\/13<\/td>\n<td>SNMP Board<\/td>\n<td>0.50a13<\/td>\n<td width=\"944\">\u2022 Disable interface. I would disable the interface only in dual bridge mode. In other cases, it is not necessary to disable eth2 because those modes require two interfaces to work properly.<br \/>\n\u2022 Remove the IP from the interface and, if DHCP is enabled, ensure it does not send DHCP queries through ETH1.<\/td>\n<\/tr>\n<tr>\n<td>2025\/11\/6<\/td>\n<td>SNMP Board<\/td>\n<td>0.50a9<\/td>\n<td width=\"944\">1. To fix permissions vulnerabilities problem.<br \/>\n2. To restrict local user logging into SSH.<br \/>\n3. To disallow &#8222;admin&#8220; as the local user name ,such as Admin, ADMIN, aDmin\u2026<br \/>\n4. To display system name in syslog instead of hostname.<br \/>\n5. To fix of ellipsis caused by too long text (**Too long string may cause the web page to break or display abnormally **).<br \/>\n8. To modify Outlet Group Description string from &#8222;The outlets use the delay periods of the lowest-numbered outlet in the group.&#8220;\u00a0 to &#8222;The outlets use the delay periods of individual outlet in the group.&#8220;<br \/>\n7. To fix the &#8222;Detail&#8220; string in Outlet Control page to be multi-language.<\/td>\n<\/tr>\n<tr>\n<td>2025\/9\/8<\/td>\n<td>SNMP Board<\/td>\n<td>0.50a8<\/td>\n<td width=\"944\">1. Enable Tx delay and Rx delay.<\/td>\n<\/tr>\n<tr>\n<td>2025\/7\/23<\/td>\n<td>SNMP Board<\/td>\n<td>0.50a7<\/td>\n<td width=\"944\">1. Enable SSH-2 cipher (enc) aes256-ctr in Dropbear by the customer request.<\/td>\n<\/tr>\n<tr>\n<td>2025\/7\/4<\/td>\n<td>SNMP Board<\/td>\n<td>0.50a6<\/td>\n<td width=\"944\">1. To add pduDevMonInletTotalCurrentPh1, pduDevMonInletTotalCurrentPh2, pduDevMonInletTotalCurrentPh3, pduDevMonInletTotalActPower in the MIB file. The MIB file will be the SPS2_MIBv1_v1.05 and SPS2_MIBv2_v1.05.<br \/>\n2. To add the PDU root certificate download function.<br \/>\n3. To update the SSH-2 protocol from SSH-2.0-dropbear_2024.85 to SSH-2.0-dropbear_2025.88.<\/td>\n<\/tr>\n<tr>\n<td>2025\/6\/20<\/td>\n<td>SNMP Board<\/td>\n<td>0.50a5<\/td>\n<td width=\"944\">1. To modify the SSH certification RSA Host Key Length from 1024 to 2048 bit.<br \/>\n2. To fix abnormal behavior of the uploaded logo.<\/td>\n<\/tr>\n<tr>\n<td>2025\/6\/6<\/td>\n<td>SNMP Board<\/td>\n<td>0.50a4<\/td>\n<td width=\"944\">1. To fix the Reactive Power display error value in the Modbus table.<br \/>\n2. To adjust the width of the serial number displayed on the webpage.<\/td>\n<\/tr>\n<tr>\n<td>2025\/3\/28<\/td>\n<td>SNMP Board<\/td>\n<td>0.50a2<\/td>\n<td width=\"944\">1. Update the Linux kernel version from 4.19.38 to 4.19.94 and update the log data sync rule to fix the firmware parameters crashing problem.<br \/>\n2. Support 48 Ports PDU by powertek request.<br \/>\n3. Modify the display sequence of the syslog, history log download, and email attachment.<br \/>\n4. Upgrade RawSocket and extend block number from 2 to 4 bytes for PDU FITility(ver.1.00.15) tools.Notes: Due to kernel version update, before upgrading firmware ver. 0.50a2, please upgrade firmware version to &#8222;NKS_0.40a29&#8220; first.<br \/>\nAfter upgrading firmware ver. 0.50a2, the board will not downgrade to firmware NKS_0.40a29 to avoid file system error issues.<\/td>\n<\/tr>\n<tr>\n<td>2025\/3\/28<\/td>\n<td>SNMP Board<\/td>\n<td>NKS_0.40a29<\/td>\n<td width=\"944\">1. Extend file size to support two Linunx kernel file for kernel version upgrade process.<\/td>\n<\/tr>\n<tr>\n<td>2025\/2\/26<\/td>\n<td>SNMP Board<\/td>\n<td>0.40a28<\/td>\n<td width=\"944\">1. To fix the slave01 outlet turn on\/off the abnormal problem.<\/td>\n<\/tr>\n<tr>\n<td>2025\/2\/11<\/td>\n<td>SNMP Board<\/td>\n<td>0.40a27<\/td>\n<td width=\"944\">1. To fix abnormal behavior of network connection based on firmware v0.40a25.<\/td>\n<\/tr>\n<tr>\n<td>2025\/1\/14<\/td>\n<td>SNMP Board<\/td>\n<td>0.40a25<\/td>\n<td width=\"944\">1. To fix abnormal behavior of the outlet during POS PDU AC failure (circuit breaker closed) and AC restoration (circuit breaker opened).<br \/>\n2. To fix the setting value of the Inlet overload alarm to the default value after the firmware is upgraded to ver. 0.40a24.<br \/>\n3. To fix the problem of the send mail failure when the PDU system restarts.<\/td>\n<\/tr>\n<tr>\n<td>2024\/12\/20<\/td>\n<td>SNMP Board<\/td>\n<td>0.40a24<\/td>\n<td width=\"944\">1. To modify critical and warning default values of the Inlet Over load alarm from (27500 and\u00a0 21000) to (100000 and 90000) for 125A CT PDU.<br \/>\n2. To Release MIB file v1.04<br \/>\n3. To modify EMD logs graphic temperature range from (-50 ~ 150) to (0 ~ 100).<br \/>\nNotes: After the firmware upgrade, the original setting value will be restored to the default value since the critical and warning field is converted from 2-bit to 4-bits to support 125A CT request.<\/td>\n<\/tr>\n<tr>\n<td>2024\/11\/8<\/td>\n<td>SNMP Board<\/td>\n<td>0.40a22<\/td>\n<td width=\"944\">1. Update German strings at Powertek&#8217;s request.<br \/>\n2. Fix temperature\/humidity calibration values of the EMD not workable.<\/td>\n<\/tr>\n<tr>\n<td>2024\/8\/27<\/td>\n<td>SNMP Board<\/td>\n<td>0.40a18<\/td>\n<td width=\"944\">1. Support 125A CT (SPEEDA CT PN# SSD-4718-2000T150L2P) then modified the related modules as webpage, snmpd and cli.<br \/>\n2. Fixed SNMPD engine ID.<br \/>\n3. Fixed multi-language display error, German is displayed as Spanish and Spanish is displayed as German.<\/td>\n<\/tr>\n<tr>\n<td>2024\/7\/4<\/td>\n<td>SNMP Board<\/td>\n<td>0.40a17<\/td>\n<td width=\"944\">1. Add dew point temperature in the Webpage but without change logs, MIB, CLI etc\u2026.<\/td>\n<\/tr>\n<tr>\n<td>2024\/4\/26<\/td>\n<td>SNMP Board<\/td>\n<td>0.40a14<\/td>\n<td width=\"944\">1. To fix AC Type RCM over 30mA then alarm cannot be triggered in the LCM.<\/td>\n<\/tr>\n<tr>\n<td>2024\/3\/29<\/td>\n<td>SNMP Board<\/td>\n<td>0.40a13-3<\/td>\n<td width=\"944\">1. To add &#8222;support SNMP v3 only feature&#8220; by Powertek requirement.<br \/>\n2. To release MIB file v1.02<\/td>\n<\/tr>\n<tr>\n<td>2025\/1\/14<\/td>\n<td>Inlet\/Outlet<\/td>\n<td>1.0.32<\/td>\n<td width=\"944\">To fix abnormal behavior of the outlet during POS PDU AC failure (circuit breaker closed) and AC restoration (circuit breaker opened).<\/td>\n<\/tr>\n<tr>\n<td>2024\/8\/21<\/td>\n<td>Inlet\/Outlet<\/td>\n<td>1.0.31<\/td>\n<td width=\"944\">1. To support 125A CT(SPEEDA, SSD-4718-2000T150L2P )<\/td>\n<\/tr>\n<tr>\n<td>2024\/3\/27<\/td>\n<td>Inlet\/Outlet<\/td>\n<td>1.0.27<\/td>\n<td width=\"944\">1. To fix outlet webpage display lag problem when turn on\/off process.<\/td>\n<\/tr>\n<tr>\n<td>2024\/3\/11<\/td>\n<td>SNMP Board<\/td>\n<td>\u00a00.40a11<\/td>\n<td width=\"944\">1. To fix outlet sequential starup problem in the 24 ports POS system.<\/td>\n<\/tr>\n<tr>\n<td>2024\/3\/11<\/td>\n<td>Inlet\/Outlet<\/td>\n<td>1.0.26<\/td>\n<td>1. To change AC voltage detection rule for DIP voltage test.<\/td>\n<\/tr>\n<tr>\n<td>2024\/3\/1<\/td>\n<td>SNMP Board<\/td>\n<td>v0.40a10<\/td>\n<td width=\"944\">1. To fix the timeout issue in upgrading inlet\/outlet firmware.<\/td>\n<\/tr>\n<tr>\n<td>2024\/2\/26<\/td>\n<td>SNMP Board<\/td>\n<td>0.40a09<\/td>\n<td>1. To fix outlet cannot be delay turned on or off when outlet number is greater than 32.<\/td>\n<\/tr>\n<tr>\n<td>2024\/2\/23<\/td>\n<td>SNMP Board<\/td>\n<td>0.40a08<\/td>\n<td width=\"944\">1. To fix SNMP client query following alarm status reporting error.<br \/>\npduDevMonInletEvtLoadBalance,<br \/>\npduDevMonInletEvtOverLoad,<br \/>\npduDevMonInletEvtStatusPh1 ~ 3<\/td>\n<\/tr>\n<tr>\n<td>2024\/2\/22<\/td>\n<td>SNMP Board<\/td>\n<td>0.40a07<\/td>\n<td width=\"944\">1. To change common name to powertekpdus.com.<br \/>\n2. To add removing certificate function on the Security page.<br \/>\n3. To fix energy was reset to 0 after system restart.<\/td>\n<\/tr>\n<tr>\n<td>2024\/2\/21<\/td>\n<td>SNMP Board<\/td>\n<td>0.40a06<\/td>\n<td width=\"944\">1. To change certificate subject according to Powertek requirements.<br \/>\n2. To fix Inlet and Outlet value during power share startup.<\/td>\n<\/tr>\n<tr>\n<td>2024\/1\/25<\/td>\n<td>SNMP Board<\/td>\n<td>0.40a04<\/td>\n<td width=\"944\">1. To fix netmask and route address conflict problem.<\/td>\n<\/tr>\n<tr>\n<td>2023\/11\/24<\/td>\n<td>SNMP Board<\/td>\n<td>0.30 a59<\/td>\n<td width=\"944\">1. Add Serial Number in General Setting webpage.<br \/>\n2. Add MAC address in TCP\/IP webpage.<br \/>\n3. Change LCM&#8217;s daisy chain PDU display name.<br \/>\n4. Change Load Balance max. threshold from 200 to 400.<br \/>\n5. Fix email cannot send issue.<\/td>\n<\/tr>\n<tr>\n<td>2023\/11\/24<\/td>\n<td>Inlet\/Outlet<\/td>\n<td>1.0.25<\/td>\n<td width=\"944\">1.\u00a0 To fixed some RCMB(DC type) incorrect actions.<\/td>\n<\/tr>\n<tr>\n<td>2023\/10\/13<\/td>\n<td>SNMP Board<\/td>\n<td>0.30 a57<\/td>\n<td width=\"944\">1. Modify firmware to support dual ethernet Standalone mode.<br \/>\n2. Update SPS2_MIBv1_v0.98 and SPS2_MIBv2_v0.98 file for dual ethernet Standalone mode support.<br \/>\n3. Fixed issue where uploaded language would disappear after system restart.<\/td>\n<\/tr>\n<tr>\n<td>2023\/9\/11<\/td>\n<td>Inlet\/Outlet<\/td>\n<td>1.0.24<\/td>\n<td width=\"944\">To fix outlet switching problem when breaker turn off in the POS system.<\/td>\n<\/tr>\n<tr>\n<td>2023\/8\/31<\/td>\n<td>SNMP Board<\/td>\n<td>0.30 a55<\/td>\n<td width=\"944\">To fix outlet energy has not matching between SNMP v2 and Webpage.<\/td>\n<\/tr>\n<tr>\n<td>2023\/8\/31<\/td>\n<td>Inlet\/Outlet<\/td>\n<td>1.0.23<\/td>\n<td width=\"944\">To fix outlet energy has not matching between SNMP v2 and Webpage.<\/td>\n<\/tr>\n<tr>\n<td>2023\/8\/18<\/td>\n<td>SNMP Board<\/td>\n<td>0.30 a54<\/td>\n<td width=\"944\">1. To fix daisy chain problem that sometimes slaves PDU will disappear in the webpage.<\/td>\n<\/tr>\n<tr>\n<td>2023\/8\/18<\/td>\n<td>Inlet\/Outlet<\/td>\n<td>1.0.22<\/td>\n<td width=\"944\">1. The Inlet board support 16A CT system assembly by Powertek system request.<\/td>\n<\/tr>\n<tr>\n<td>2023\/8\/10<\/td>\n<td>SNMP Board<\/td>\n<td>0.30 a53<\/td>\n<td width=\"944\">1. To fix daisy chain problem that sometimes slaves PDU will disappear in the webpage.<br \/>\nThe total cable length of the daisy chain will be 20 meters for 16pcs PDU.<br \/>\n2. To fix the network instability problem that enhance dual Ethernet mode solution.<\/td>\n<\/tr>\n<tr>\n<td>2023\/6\/30<\/td>\n<td>SNMP Board<\/td>\n<td>0.30 a51<\/td>\n<td width=\"944\">1. Remove &#8222;Type&#8220; from Inlet display screen of the DFSTN LCM and OLED.<\/td>\n<\/tr>\n<tr>\n<td>2023\/6\/20<\/td>\n<td>Inlet\/Outlet<\/td>\n<td>1.0.21<\/td>\n<td width=\"944\">1. To fix sequential startup abnormal and outlet disappear problem in the POS system.<\/td>\n<\/tr>\n<tr>\n<td>2023\/6\/13<\/td>\n<td>Inlet\/Outlet<\/td>\n<td>1.0.20<\/td>\n<td width=\"944\">1. To fix sequential startup abnormal and outlet disappear problem in the POS system.<\/td>\n<\/tr>\n<tr>\n<td>2023\/6\/7<\/td>\n<td>Inlet\/Outlet<\/td>\n<td>1.0.19<\/td>\n<td width=\"944\">To fix volts abnormal display of the Inlet L2&amp;L3.<\/td>\n<\/tr>\n<tr>\n<td>2023\/5\/26<\/td>\n<td>SNMP Board<\/td>\n<td>0.30 a50<\/td>\n<td width=\"944\">1. Fix parameters crash problem.<br \/>\n2. Add SNMPv3 USM table MIB file.<br \/>\n3. If system name is default value (default: PDU), then DHCP hostname attached with system name and mac address, otherwise, only attached system name.<br \/>\n4. Change system name default value from Powertek to PDU. (Only at first time upgrade to this version will working, ex. Upgrade from TI MFG FW to this version)<br \/>\n5. Change LCM type default value from STN to OLED. (Only at first time upgrade to this version will working, ex. Upgrade from TI MFG FW to this version)<br \/>\n6. Change PDU Type default value from 3 phase PDU 250V 32A to 3 phase PDU 380 32A. (Only at first time upgrade to this version will working, ex. Upgrade from TI MFG FW to this version)<br \/>\n7. Release new MIB file SPS2_MIBv1_v0.97.mib and SPS2_MIBv2_v0.97.mib.<\/td>\n<\/tr>\n<tr>\n<td>2023\/5\/26<\/td>\n<td>Inlet\/Outlet<\/td>\n<td>1.0.18<\/td>\n<td width=\"944\">1. Added current filtering method, when the current value is negative, this value is forced to be set to zero.<br \/>\n2. AC fault detection is forced disabled when the board is a non-relay type.<\/td>\n<\/tr>\n<tr>\n<td>2023\/4\/28<\/td>\n<td>SNMP Board<\/td>\n<td>0.30 a48<\/td>\n<td width=\"944\">1. SNMPV3 user table array size change 1 to 8. (Change scope included webpage and CLI)<br \/>\n2. Release CLI file (PDU2 CLI_20230410.xlsx).<br \/>\n3. Release REST API V2.7(New Banchao REST API_2023_0410.docx).<\/td>\n<\/tr>\n<tr>\n<td>2023\/3\/31<\/td>\n<td>SNMP Board<\/td>\n<td>0.30 a47<\/td>\n<td width=\"944\">1. Fix browser language switching cause webpage display error.<br \/>\n2. Support SPD. (When SPD trigger, LCM show warning). The SNMP board and Inlet hardware version must be ver. A3.<\/td>\n<\/tr>\n<tr>\n<td>2023\/3\/29<\/td>\n<td>SNMP Board<\/td>\n<td>0.30 a46<\/td>\n<td width=\"944\">1. Fix sequential on outlet state not sync with last state object at first time upgrade to new version.<\/td>\n<\/tr>\n<tr>\n<td>2023\/3\/25<\/td>\n<td>SNMP Board<\/td>\n<td>0.30 a44<\/td>\n<td width=\"944\">1. Add Outlet Sequential Startup\u00a0 Feature.<\/td>\n<\/tr>\n<tr>\n<td>2023\/3\/24<\/td>\n<td>Inlet\/Outlet<\/td>\n<td>1.0.17<\/td>\n<td width=\"944\">1. Add Outlet Sequential Startup\u00a0 Feature.<\/td>\n<\/tr>\n<tr>\n<td>2023\/3\/8<\/td>\n<td>SNMP Board<\/td>\n<td>0.30 a43<\/td>\n<td width=\"944\">1. Fix outlet disappear problem.<br \/>\n2. Fix LCM jump time error problem.<br \/>\n3. Change power factor display unit (ex. 94 %-&gt; 0.94), includes web, MIB, cli, Modbus and mail attached file.<br \/>\n4. Release new mib file SPS2_MIBv1_v0.96.mib and SPS2_MIBv2_v0.96.mib.<\/td>\n<\/tr>\n<tr>\n<td>2023\/3\/8<\/td>\n<td>Inlet\/Outlet<\/td>\n<td>1.0.16<\/td>\n<td width=\"944\">1. Fix outlet disappear problem.<\/td>\n<\/tr>\n<tr>\n<td>2023\/1\/19<\/td>\n<td>Inlet\/Outlet<\/td>\n<td>1.0.13<\/td>\n<td width=\"944\">1. To implement the relay is forced to close when the power is off, Start the ON delay function after power on.<br \/>\n2. To correct the Outlet power calculation problem, when the current is too large (&gt;20A), the calculation will be wrong.<\/td>\n<\/tr>\n<tr>\n<td>2023\/1\/19<\/td>\n<td>SNMP Board<\/td>\n<td>0.30 a40<\/td>\n<td width=\"944\">1. To add hostname to DHCP command.<br \/>\n2. To hide Residual Current(mA) Alarm Threshold when RCMB is invalid.<\/td>\n<\/tr>\n<tr>\n<td>2022\/12\/23<\/td>\n<td>Inlet\/Outlet<\/td>\n<td>1.0.12<\/td>\n<td width=\"944\">1. Fix the small current error problem, Clear current\/power\/PF when the current is below 0.01A.<br \/>\n2. Modify the calculation formula of power (active\/apparent\/reactive).<\/td>\n<\/tr>\n<tr>\n<td>2022\/11\/17<\/td>\n<td>SNMP Board<\/td>\n<td>0.30 a39<\/td>\n<td width=\"944\">1. Support BENDVAC RCMB 121-1 (DC Type) and RCMB 121-2 (AC Type).<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row content_width=&#8220;grid&#8220; css=&#8220;.vc_custom_1612187139645{margin-top: 50px !important;margin-bottom: 50px !important;}&#8220;][vc_column][vc_column_text]<\/p>\n<h2>PIML PDUs FIRMWARE<\/h2>\n<p>[\/vc_column_text][vc_empty_space height=&#8220;20px&#8220;][vc_column_text css=&#8220;.vc_custom_1612194577707{padding-bottom: 25px !important;}&#8220;]Download the latest firmware version:[\/vc_column_text][vc_row_inner content_width=&#8220;grid&#8220;][vc_column_inner width=&#8220;1\/2&#8243; css=&#8220;.vc_custom_1612192860734{padding-bottom: 15px !important;}&#8220;][vc_column_text]PIML FIRMWARE LAST VERSION<\/p>\n<p>Steps for upgrade firmware after download:<\/p>\n<p>1- Install GIGA SNMP on Advanced &#8212; Maintenance menu &#8212; Firmware Update[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8220;1\/2&#8243;][vc_btn title=&#8220;PIML SNMP DOWNLOAD&#8220; style=&#8220;custom&#8220; custom_background=&#8220;#145c9f&#8220; custom_text=&#8220;#ffffff&#8220; shape=&#8220;square&#8220; link=&#8220;url:https%3A%2F%2Fwww.powertekpdus.com%2Fwp-content%2Fuploads%2F2023%2F05%2FSTORK-PDU_Sps-FW-IMG_v1.01_a15-fw_0518.bin|target:_blank&#8220;][\/vc_column_inner][\/vc_row_inner][vc_row_inner content_width=&#8220;grid&#8220;][vc_column_inner width=&#8220;1\/2&#8243; css=&#8220;.vc_custom_1612192860734{padding-bottom: 15px !important;}&#8220;][vc_column_text]PIML FIRMWARE LAST VERSION<\/p>\n<p>Steps for upgrade firmware after download:<\/p>\n<p>1- Unzip the file and install on Advanced &#8212; Inlet &amp; Outlet upgrade[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8220;1\/2&#8243;][vc_btn title=&#8220;PIML INLET UPGRADE&#8220; style=&#8220;custom&#8220; custom_background=&#8220;#145c9f&#8220; custom_text=&#8220;#ffffff&#8220; shape=&#8220;square&#8220; link=&#8220;url:https%3A%2F%2Fwww.powertekpdus.com%2Fwp-content%2Fuploads%2F2023%2F06%2FFW-IMG-v1.0.21_20230619.zip|target:_blank&#8220;][\/vc_column_inner][\/vc_row_inner][vc_empty_space height=&#8220;50px&#8220;][vc_column_text]<\/p>\n<h2>Firmware history<\/h2>\n<p>[\/vc_column_text][vc_empty_space height=&#8220;20px&#8220;][vc_column_text css=&#8220;.vc_custom_1664018138043{padding-bottom: 25px !important;}&#8220;]&#8212; Revision History<br \/>\n&#8212;<br \/>\n&#8212; v0.10 09-Dec-2020 Grace Wu Created<br \/>\n&#8212;<br \/>\n&#8212;<br \/>\n&#8212; v0.20 05-Feb-2021 Kenneth change OID to simple(2) for pwt(4)<br \/>\n&#8212;<br \/>\n&#8212;<br \/>\n&#8212; v0.30 20-Feb-2021 Grace Wu<br \/>\n&#8212; 1. pduEmdCurrInfoHumidityStat SYNTAX INTEGER change to normal(1),warning(2),critical(3).<br \/>\n&#8212; 2. pduEmdCurrInfoTempStat SYNTAX INTEGER change to normal(1),warning(2),critical(3).<br \/>\n&#8212; 3. pduEmdCfgEMDAddress change to read-only.<br \/>\n&#8212; 4. pduEmdCfgAppFWVer change to read-only.<br \/>\n&#8212; 6. pduEmdCfgTempCalOffset SYNTAX INTEGER change to fivePointFour(1),fourPointFive(2),<br \/>\n&#8212; threePointSix(3),twoPointSeven(4),onePointEight(5),zeroPointNine(6),zeroPointZero(7),<br \/>\n&#8212; negativeZeroPointNine(8),negativeOnePointEight(9),negativeTwoPointSeven(10),<br \/>\n&#8212; negativeThreePointSix(11),negativeFourPointFive(12),negativeFivePointFour(13).<br \/>\n&#8212; 7. pduEmdCfgHumidityCalOffset SYNTAX INTEGER change to six(1),five(2),four(3),three(4),two(5),<br \/>\n&#8212; one(6),zero(7),negativeOne(8),negativeTwo(9),negativeThree(10),<br \/>\n&#8212; negativeFour(11),negativeFive(12),negativeSix(13).<br \/>\n&#8212; 8. pduDateAndTimeNtpSyncIntervalType change day to 1, month to 2.<br \/>\n&#8212; 9. pduIecViewMgmtGuid change to read-only.<br \/>\n&#8212; 10. pduAccessIpSettingTblAction accept-&gt;allow,reject-&gt;deny.<br \/>\n&#8212; 11. pduEmdCfgTempCritHigh SYNTAX INTEGER change to 0..650.<br \/>\n&#8212; 12. pduEmdCfgTempCritLow SYNTAX INTEGER change to 0..650.<br \/>\n&#8212; 13. pduEmdCfgTempWarnHigh SYNTAX INTEGER change to 0..650.<br \/>\n&#8212; 14. pduEmdCfgTempWarnLow SYNTAX INTEGER change to 0..650.<br \/>\n&#8212; 15. pduNetServiceRadiusTimeout SYNTAX INTEGER change to 1..99.<br \/>\n&#8212; 16. pduNetServiceRadiusRetry SYNTAX INTEGER change to 1..99.<br \/>\n&#8212; 17. pduSnmpSettingTrapEvtLevel SYNTAX INTEGER change to informational(1),warning(2),critical(3).<br \/>\n&#8212; 18. pduEmailSettingSmtpAuthEn SYNTAX INTEGER change to disabled(1),enabled(2)<br \/>\n&#8212; 19. trap change some description.<br \/>\n&#8212;<br \/>\n&#8212;<br \/>\n&#8212; v0.40 22-Feb-2021 Grace Wu<br \/>\n&#8212; 1. pduIpv6SettingAddress change to pduIpv6SettingLocalAddress and change to read.<br \/>\n&#8212; 2. add pduIpv6SettingGlobalAddress.<br \/>\n&#8212; 3. pduIpv6SettingPrefix range change from 0-63 to 0-128<br \/>\n&#8212;<br \/>\n&#8212;<br \/>\n&#8212; v0.50 04-Mar-2021 Grace Wu<br \/>\n&#8212; 1. pduCfgCritOverLoadAlm unit changet to 0.1W, and range change to 0-140800.<br \/>\n&#8212; 2. pduCfgCritLoadBalanceAlm unit changet to 0.1%, and range change to 0-1000.<br \/>\n&#8212; 3. pduCfgWarnOverLoadAlm unit changet to 0.1W, and range change to 0-140800.<br \/>\n&#8212; 4. pduCfgWarnLoadBalanceAlm unit changet to 0.1%, and range change to 0-1000.<br \/>\n&#8212; 5. pduEmdCurrInfoHumidityValue unit changet to 0.1%.<br \/>\n&#8212; 6. pduEmdCfgTempCritHigh add unit 0.1.<br \/>\n&#8212; 7. pduEmdCfgTempCritLow add unit 0.1.<br \/>\n&#8212; 8. pduEmdCfgTempWarnHigh add unit 0.1.<br \/>\n&#8212; 9. pduEmdCfgTempWarnLow add unit 0.1.<br \/>\n&#8212; 10. Critical: Cold boot. -&gt; coldStart.<br \/>\n&#8212; 11. Critical: Warm boot. -&gt; warmStart.<br \/>\n&#8212; 12. add trap pduInletCurrCB2Phase1Warn(71)~pduInletCurrPhase3CB2CritToWarn(82).<br \/>\n&#8212; 13. trap pduInletCurrPhase1Warn(15)~pduInletCurrPhase3CritToWarn(26) name add CB1.<br \/>\n&#8212;<br \/>\n&#8212;<br \/>\n&#8212; v0.60 12-Mar-2021 Grace Wu<br \/>\n&#8212; 1. remove pduIpv6SettingPrefix.[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row content_width=&#8220;grid&#8220; css=&#8220;.vc_custom_1612187139645{margin-top: 50px !important;margin-bottom: 50px !important;}&#8220;][vc_column][vc_column_text] GIGA PDUs FIRMWARE [\/vc_column_text][vc_empty_space height=&#8220;20px&#8220;][vc_column_text css=&#8220;.vc_custom_1612194577707{padding-bottom: 25px !important;}&#8220;]Download the latest firmware version:[\/vc_column_text][vc_row_inner content_width=&#8220;grid&#8220;][vc_column_inner width=&#8220;1\/2&#8243; css=&#8220;.vc_custom_1612192860734{padding-bottom: 15px !important;}&#8220;][vc_column_text]LAST FIRMWARE UPGRADE Install this file if you already have version 40a29 or 50axxxx 1- Install GIGA SNMP on Advanced &#8212; Maintenance&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":6249,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-6823","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Last firmware updates - Powertek<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.powertekpdus.com\/de\/ressourcen\/firmware-downloads\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Last firmware updates - Powertek\" \/>\n<meta property=\"og:description\" content=\"[vc_row content_width=&#8220;grid&#8220; css=&#8220;.vc_custom_1612187139645{margin-top: 50px !important;margin-bottom: 50px !important;}&#8220;][vc_column][vc_column_text] GIGA PDUs FIRMWARE [\/vc_column_text][vc_empty_space height=&#8220;20px&#8220;][vc_column_text css=&#8220;.vc_custom_1612194577707{padding-bottom: 25px !important;}&#8220;]Download the latest firmware version:[\/vc_column_text][vc_row_inner content_width=&#8220;grid&#8220;][vc_column_inner width=&#8220;1\/2&#8243; css=&#8220;.vc_custom_1612192860734{padding-bottom: 15px !important;}&#8220;][vc_column_text]LAST FIRMWARE UPGRADE Install this file if you already have version 40a29 or 50axxxx 1- Install GIGA SNMP on Advanced &#8212; Maintenance...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.powertekpdus.com\/de\/ressourcen\/firmware-downloads\/\" \/>\n<meta property=\"og:site_name\" content=\"Powertek\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-22T09:11:01+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"1\u00a0Minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.powertekpdus.com\\\/de\\\/ressourcen\\\/firmware-downloads\\\/\",\"url\":\"https:\\\/\\\/www.powertekpdus.com\\\/de\\\/ressourcen\\\/firmware-downloads\\\/\",\"name\":\"Last firmware updates - Powertek\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.powertekpdus.com\\\/de\\\/#website\"},\"datePublished\":\"2021-01-14T14:26:06+00:00\",\"dateModified\":\"2026-06-22T09:11:01+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.powertekpdus.com\\\/de\\\/ressourcen\\\/firmware-downloads\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.powertekpdus.com\\\/de\\\/ressourcen\\\/firmware-downloads\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.powertekpdus.com\\\/de\\\/ressourcen\\\/firmware-downloads\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.powertekpdus.com\\\/de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Ressourcen\",\"item\":\"https:\\\/\\\/www.powertekpdus.com\\\/de\\\/ressourcen\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Last firmware updates\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.powertekpdus.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/www.powertekpdus.com\\\/de\\\/\",\"name\":\"Powertek\",\"description\":\"A New Era in Power Distribution\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.powertekpdus.com\\\/de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Last firmware updates - Powertek","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.powertekpdus.com\/de\/ressourcen\/firmware-downloads\/","og_locale":"de_DE","og_type":"article","og_title":"Last firmware updates - Powertek","og_description":"[vc_row content_width=&#8220;grid&#8220; css=&#8220;.vc_custom_1612187139645{margin-top: 50px !important;margin-bottom: 50px !important;}&#8220;][vc_column][vc_column_text] GIGA PDUs FIRMWARE [\/vc_column_text][vc_empty_space height=&#8220;20px&#8220;][vc_column_text css=&#8220;.vc_custom_1612194577707{padding-bottom: 25px !important;}&#8220;]Download the latest firmware version:[\/vc_column_text][vc_row_inner content_width=&#8220;grid&#8220;][vc_column_inner width=&#8220;1\/2&#8243; css=&#8220;.vc_custom_1612192860734{padding-bottom: 15px !important;}&#8220;][vc_column_text]LAST FIRMWARE UPGRADE Install this file if you already have version 40a29 or 50axxxx 1- Install GIGA SNMP on Advanced &#8212; Maintenance...","og_url":"https:\/\/www.powertekpdus.com\/de\/ressourcen\/firmware-downloads\/","og_site_name":"Powertek","article_modified_time":"2026-06-22T09:11:01+00:00","twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"1\u00a0Minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.powertekpdus.com\/de\/ressourcen\/firmware-downloads\/","url":"https:\/\/www.powertekpdus.com\/de\/ressourcen\/firmware-downloads\/","name":"Last firmware updates - Powertek","isPartOf":{"@id":"https:\/\/www.powertekpdus.com\/de\/#website"},"datePublished":"2021-01-14T14:26:06+00:00","dateModified":"2026-06-22T09:11:01+00:00","breadcrumb":{"@id":"https:\/\/www.powertekpdus.com\/de\/ressourcen\/firmware-downloads\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.powertekpdus.com\/de\/ressourcen\/firmware-downloads\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.powertekpdus.com\/de\/ressourcen\/firmware-downloads\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.powertekpdus.com\/de\/"},{"@type":"ListItem","position":2,"name":"Ressourcen","item":"https:\/\/www.powertekpdus.com\/de\/ressourcen\/"},{"@type":"ListItem","position":3,"name":"Last firmware updates"}]},{"@type":"WebSite","@id":"https:\/\/www.powertekpdus.com\/de\/#website","url":"https:\/\/www.powertekpdus.com\/de\/","name":"Powertek","description":"A New Era in Power Distribution","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.powertekpdus.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"}]}},"_links":{"self":[{"href":"https:\/\/www.powertekpdus.com\/de\/wp-json\/wp\/v2\/pages\/6823","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.powertekpdus.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.powertekpdus.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.powertekpdus.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.powertekpdus.com\/de\/wp-json\/wp\/v2\/comments?post=6823"}],"version-history":[{"count":68,"href":"https:\/\/www.powertekpdus.com\/de\/wp-json\/wp\/v2\/pages\/6823\/revisions"}],"predecessor-version":[{"id":9741,"href":"https:\/\/www.powertekpdus.com\/de\/wp-json\/wp\/v2\/pages\/6823\/revisions\/9741"}],"up":[{"embeddable":true,"href":"https:\/\/www.powertekpdus.com\/de\/wp-json\/wp\/v2\/pages\/6249"}],"wp:attachment":[{"href":"https:\/\/www.powertekpdus.com\/de\/wp-json\/wp\/v2\/media?parent=6823"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}